Showing results: 646 - 660 of 1516 items found.
-
40-675A-002-198/1 -
Pickering Interfaces Ltd.
The 40-675A-002-198/1 is a 198-channel, 1-pole MUX and is part of our range of PXI very high density low cost multiplexer modules. These modules are suitable for signal routing in high channel count ATE and data acquisition systems. The modules use high quality electromechanical signal relays allowing each channel to switch current up to 1A at 150VDC/100VAC. Connections are made via a front panel 200-pin connector.
-
Arduino 4 Relays Shield -
Arduino llc
The Arduino 4 Relays Shield is a solution for driving high power loads that cannot be controlled by Arduino's digital IOs, due to the current and voltage limits of the controller. The Shield features four relays, each relay provides 2 pole changeover contacts (NO and NC); in order to increase the current limit of each output the 2 changeover contacts have been put in parallel. Four LEDs indicate the on/off state of each relay.
-
Yangzhou Power Electric Co., Ltd
High current test systems are used to test the thermal stability of equipment and components. The test system induces a current in the test object causing it to heat up.The system can perform the heat cycle testing for power cables type test and pre-qualification test according to IEC 60840, and IEC 62067 etc. Based on pre-qualification test needs, test system is divided into two parts: test sample loop and simulation temperature loop.
-
TS2X020 -
Intelligent Charging
The TS2X020 is a portable lightweight battery charger intended for rapid charging of vehicle batteries in the field without the attendant weight penalties usually associated with the operation. The charger is a constant voltage unit, and the charging current is regulated by the battery terminal voltage, with current limit of 20 Amps on 24v output, and 40 Amps on 12v output. Switch mode technology provides high efficiency; both in power to weight ratio, and input to output ratio.
-
Bender Inc.
Neutral Grounding Resistors (NGRs) are used to limit the maximum ground-fault current. Restriction of fault current lowers hazards and reduces damage done to equipment. High Resistance Grounding (HRG) systems are often used on industrial and critical power applications to maintain system uptime during a first ground fault. HRG systems are also used in tripping applications to help control touch potential on portable loads and improve personnel safety.
-
72-7655 -
Tenma
High current switch mode power supply with remote sensing and control.*Bright 3 digit dual LED displays*Simultaneous display of output voltage and current*Excellent load and line regulation*Low ripple and noise*Overload (constant current limiting), short circuit, over temperature and OVP protections*Variable speed thermal static control fan for cooling*Highly efficient active power factor corrector*Front panel banana jacks for loads up to 5A*Rear panel binding posts for loads up to 60A*12-month limited warranty *view Terms & Conditions for details
-
Weshine Electric Manufacturing Co., Ltd
1. The current, voltage and waveform data are directly obtained from the high voltage side, so the data is accurate.2. It has over-voltage protection function. When the output exceeds the set voltage limit, the instrument will stop for protection, and the action time is less than 20ms.3. It has over-current protection function: it is designed as high-voltage and low-voltage dual protection, and the high-voltage side can carry out accurate shutdown protection according to the set value; when the current on the low-voltage side exceeds the rated current, it will carry out shutdown protection, and the action time is less than 20ms.
-
FECVF1600 -
Frothingham Electronics Corporation
The VF1600 Test Station is a high current forward pulser designed to be used in conjunction with our FEC200E tester. This gives you all the versatility of the proven FEC200 with the addition of much higher forward current. The VF1600 station can produce a maximum current of 1600A at up to 5V using an 8.3 mS half sine waveform at the built in test station, and THETA and DVF tests at up to 500A at 10mS pulse width. It is derated for wider pulses. For rectangular VF pulses at 300us or 1ms, it can produce up to 2000A. The station can also test all of the usual FEC200 tests in the same test program.
-
Extech DVA30 -
Extech Instruments Corporation
The DVA30 is the only two-in-one current/voltage detector designed for electrical testing. It detects AC voltage from 12-Volt to 600V and AC current from 200 mA at 0.2 in. distance and at much greater distances for larger current flow up to 1000 Amps. Sensitivity adjustments increase or reduce sensor trigger threshold. Audible and visual indicators show the presence of current or voltage. It can be used to trace concealed wires in walls and floors, identify hot wires, trace current flow where voltage detection does not work (behind walls, in conduits, through concrete, or underground). The sensitivity is high enough to trip on low voltage HVAC or similar signal levels. Complete with four LR44 button batteries and pocket clip.
-
H62004700 -
6TL Engineering
This module is ideal for switching up to 12A. Composed by eight relays organized in two trees of four with two relays (One in each tree) with NC contact available. The module is shielded in order to reduce the radiated interference in high current switchings.
-
DBT Series -
High Voltage Inc.
DBT Series benchtop models are ideal for testing medium and high voltage electrical components and apparatus requiring DC withstand testing or a DC current leakage measurement (hipot test). These products are housed in benchtop cabinets for industrial and commercial markets.
-
NovusEdge -
Onto Innovation
The NovusEdge System provides high sensitivity inspection for the edge and backside of bare unpatterned wafers for current and advanced nodes. Multiple modules can be configured on the same automation platform for increased throughput while maintaining a small footprint for an improved cost of ownership.
-
VX Instruments GmbH
Source and Measurement Units (SMUs) are devices that generate voltages or currents and can measure them simultaneously using the integrated measuring units (VMU, CMU).High-voltage SMUs work as a regulated voltage source and are able to generate very high output voltages.
-
Osborne Transformer Corp.
Osborne designs and produces high impedance and unregulated Filament Transformers. An unregulated filament transformer supplies a specified voltage and current to the filament of an electron vacuum tube. High impedance filament transformers are designed around a tungsten tube filament. Osborne often works with our clients to increase the life-span of their vacuum tubes through the use of a regulated voltage supply.
-
HH2205C -
Colluck Company Limited
High Accuracy (Basic Accuracy 0.5%). 3-1/2 Jumbo LCD display 2000 count with symbolic signs and back light. Double Injection Casing. Manual Ranging High Voltage test up to 1000V DC and 700V AC. Higher Current test up to 20A AC/DC. Diode and Continuity check. Measure Resistance up to 20M ohm